  • Question 1 - A patient visits the radiology department for a magnetic resonance imaging (MRI) scan...

    Incorrect

    • A patient visits the radiology department for a magnetic resonance imaging (MRI) scan (MRI). The presence of metal implants must be ruled out prior to the scan. In a strong magnetic field, which of the following metals is the safest?

      Your Answer: Nickel

      Correct Answer: Chromium

      Explanation:

      Ferromagnetism is the property of a substance that is magnetically attracted and can be magnetised indefinitely. A material is said to be paramagnetic if it is attracted to a magnetic field. A substance is said to be diamagnetic if it is repelled by a magnetic field.

      Cobalt, iron, gadolinium, neodymium, and nickel are ferromagnetic.

      Gadolinium is a ferromagnetic rare earth metal that is ferromagnetic below 20 degrees Celsius (its Curie temperature). MRI scans are enhanced with gadolinium-based contrast media.

      When ferromagnetic materials are exposed to a magnetic field, they can cause a variety of issues like magnetic field interactions, heating, and image artefacts.

      Titanium, lead, chromium, copper, aluminium, silver, gold, and tin are non ferromagnetic.

    • This question is part of the following fields:

      • Clinical Measurement
      21.6
      Seconds
  • Question 2 - Which statement is the most accurate when describing electrical equipment and shock? ...

    Correct

    • Which statement is the most accurate when describing electrical equipment and shock?

      Your Answer: Type CF is considered to safe for direct connection with the heart

      Explanation:

      There are different classes of electrical equipment that can be classified in the table below:

      Class 1 – provides basic protection only. It must be connected to earth and insulated from the mains supply

      Class II – provides double insulation for all equipment. It does not require an earth.

      Class III – uses safety extra low voltage (SELV) which does not exceed 24 V AC. There is no risk of gross electrocution but risk of microshock exists.

      Type B – All of above with low leakage currents (0.5mA for Class IB, 0.1 mA for Class IIB)

      Type BF – Same as with other equipment but has ‘floating circuit’ which means that the equipment applied to patient is isolated from all its other parts.

      Type CF – Class I or II equipment with ‘floating circuits’ that is considered to be safe for direct connection with the heart. There are extremely low leakage currents (0.05mA for Class I CF and 0.01mA for Class II CF).

    • This question is part of the following fields:

      • Clinical Measurement
      13.9
      Seconds
  • Question 3 - A 73-year-old woman is admitted to the coronary care unit. She has been...

    Correct

    • A 73-year-old woman is admitted to the coronary care unit. She has been diagnosed with an acute myocardial infarction and has gone into a cardiogenic shock. As part of her treatment, she is prescribed a dobutamine infusion and placed on full haemodynamic monitoring. Over the next four days, her measurement are: Day1 Day2 Day3 Day4 Infusion rate of dobutamine (mcg/kg/min): 5, 10, 15, 25. Cardiac output (L/min): 3.4, 3.2, 3.1, 3.2. Pulse rate (beats/min): 110, 112, 105, 100. Blood pressure (mmHg): 80/60, 75/61, 83/60, 81/56. Haemodynamic changes are noted as a result of response to treatment. What is the most probable cause?

      Your Answer: Tolerance by down-regulation of beta1 receptors

      Explanation:

      Tachyphylaxis is the swiftly declining response to successive drug doses which vastly reduces its effectiveness in a short space of time, mostly as a result of an acute consumption of neurotransmitters.

      Tolerance or desensitisation is the slow decline in a person’s reaction to a drug due to continued use. It requires a longer time span than tachyphylaxis, usually over days or weeks.

      Down- regulation is a reduction in the amount of receptors available on target cells which decreases the affinity of the agent to the cells. For this to occur, the down-regulation of receptors must occur at a rate faster than receptor synthesis. This down-regulation often occurs with beta1 receptors due to:

      1) The transportation or receptors from the cell surface to the interior of the cell

      2) Degradation of receptors occurring over time.

      In this case, dobutamine is prescribed to treat cardiogenic shock. It is able to function by binding to beta1-adrenergic receptors to increase the contraction of the heart, thereby improving cardiac output. It also binds to beta2- and alpha1-adrenergic receptors to balance out the effects produced by binding to beta1 receptors and reduce the risk of system vasculature responses.

    • This question is part of the following fields:

      • Clinical Measurement
      63.7
      Seconds
  • Question 4 - A 32-year-old male is admitted to the critical care unit. He has suffered...

    Correct

    • A 32-year-old male is admitted to the critical care unit. He has suffered a heroin overdose and requires intubation and ventilatory support. What would be his predicted total static compliance (lung and chest wall) measurements.

      Your Answer: 100 ml/cmH2O

      Explanation:

      Static lung compliance refers to the change in volume within the lung per given change in unit pressure. It is usually measured when air flow is absent, such as during pauses in inhalation and exhalation.

      It is a combination of:

      Chest wall compliance: normal value is 200 mL/cmH2O
      Lung tissue compliance: normal value is 200 mL/ cmH2O

      It is represented mathematically as:

      1/Crs = 1/Cl + 1/Ccw

      Where,

      Crs = total compliance of the respiratory system
      Cl = compliance of the lung
      Ccw = compliance of the chest wall

      Therefore in this case:

      1/Crs = 1/200 + 1/200

      1/Crs = 0.005 + 0.005 = 0.01

      1/Ct = 0.01

      Rearranging equation gives:

      Ct = 1/0.01 = 100 mL/cmH2O.

    • This question is part of the following fields:

      • Clinical Measurement
      29.8
      Seconds
  • Question 5 - A 76-year-old female, presents to her GP. She complains of fatigue and increased...

    Correct

    • A 76-year-old female, presents to her GP. She complains of fatigue and increased shortness of breath. On examination, she is noted to have pallor, an increased respiratory and heart rate. Her GP requests further diagnostic investigations, including a full blood count (FBC) which finds decreased MCV and MCHC. What is the most likely cause of her symptoms?

      Your Answer: Iron deficiency

      Explanation:

      The patient’s diagnosis is microcytic hypochromic anaemia which is often as a result of iron deficiency and thalassaemia.

      Macrocytic anaemia is often caused by folate and B12 deficiencies and alcohol abuse.

      Normocytic normochromic anaemia is often caused by acute blood loss, haemolytic anaemia, anaemia of chronic disease and leucoerythroblastic anaemias.

    • This question is part of the following fields:

      • Clinical Measurement
      6.4
      Seconds
  • Question 6 - A 27-year-old woman arrives at the emergency room after intentionally ingesting 2 g...

    Correct

    • A 27-year-old woman arrives at the emergency room after intentionally ingesting 2 g of amitriptyline. A Glasgow coma score of 6 was discovered, as well as a pulse rate of 140 beats per minute and a blood pressure of 80/50 mmHg. Which of the following ECG changes is most likely to indicate the onset of life-threatening arrhythmias?

      Your Answer: Prolongation of the QRS complex

      Explanation:

      Arrhythmias and/or hypotension are the most common causes of death from tricyclic antidepressant (TCA) overdose.

      The quinidine-like actions of tricyclic antidepressants on cardiac tissues are primarily responsible for their toxicity. Conduction through the His-Purkinje system and the myocardium slows as phase 0 depolarisation of the action potential slows. QRS prolongation and atrioventricular block are caused by slowed impulse conduction, which also contributes to ventricular arrhythmias and hypotension.

      Arrhythmias can also be caused by abnormal repolarization, impaired automaticity, cholinergic blockade, and inhibition of neuronal catecholamine uptake, among other things.

      Acidaemia, hypotension, and hyperthermia can all exacerbate toxicity.

      The anticholinergic effects of tricyclic antidepressants, as well as the blockade of neuronal catecholamine reuptake, cause sinus tachycardia. Sinus tachycardia is usually well tolerated and does not require treatment. It can be difficult to tell the difference between sinus tachycardia and ventricular tachycardia with QRS prolongation.

      A QRS duration of more than 100 milliseconds indicates a higher risk of arrhythmia and should be treated with systemic sodium bicarbonate.

      The tricyclic is dissociated from myocardial sodium channels by serum alkalinization, and the extracellular sodium load improves sodium channel function.

    • This question is part of the following fields:

      • Clinical Measurement
      25.8
      Seconds
  • Question 7 - Which measurements is the most accurate for predicting fluid responsiveness? ...

    Correct

    • Which measurements is the most accurate for predicting fluid responsiveness?

      Your Answer: Change in stroke volume following passive straight leg raise

      Explanation:

      The passive leg raising (PLR) manoeuvre is a method of altering left and right ventricular preload and it is done with real-time measurement of stroke volume. It is a simple, quick, relatively unbiased, and accurate bedside test to guide fluid management and avoid fluid overload.

      Pulse pressure variation (PPV), Stroke volume variation (SVV), superior vena cava diameter variation (threshold 36%) and end-expiratory occlusion test are used for dynamic tests of fluid responsiveness.

      PPV is derived peripherally from the arterial pressure waveform.

      Stroke volume variation (SVV) can be derived peripherally through pulse contour analysis of the arterial waveform. PPV and SVV have a threshold of 12% but since they are not used in patients who have cardiac arrhythmias, are spontaneous breathing, and in ventilated patients with low lung compliance and tidal volumes, they are of limited value.

      The tests of fluid responsiveness’ accuracy is determined by calculating the area under the receiver operating characteristic curve (UROC) obtained by plotting the sensitivity of the parameter in predicting fluid responsiveness vs. 1-specificity.

      Under optimal conditions, the ability to determine the need for fluid is best with PPV>SVV>LVEDA>CVP.

      Central venous pressure (CVP) is a static test of preload (not preload responsiveness) and a key determinant of cardiac function. The left ventricular end-diastolic area (LVEDA) a static test of fluid responsiveness, is derived using echocardiography.

    • This question is part of the following fields:

      • Clinical Measurement
      36
      Seconds
  • Question 8 - Which of the following statements is false when considering the electrical safety of...

    Incorrect

    • Which of the following statements is false when considering the electrical safety of equipment?

      Your Answer: Type CF equipment is considered to safe for direct connection with the heart

      Correct Answer: The low leakage currents limit is 0.01mA for Class I CF

      Explanation:

      There are different classes of electrical equipment that can be classified in the table below:

      Class 1 – provides basic protection only. It must be connected to earth and insulated from the mains supply

      Class II – provides double insulation for all equipment. It does not require an earth.

      Class III – uses safety extra low voltage (SELV) which does not exceed 24 V AC. There is no risk of gross electrocution but risk of microshock exists.

      Type B – All of above with low leakage currents (0.5mA for Class IB, 0.1 mA for Class IIB)

      Type BF – Same as with other equipment but has ‘floating circuit’ which means that the equipment applied to patient is isolated from all its other parts.

      Type CF – Class I or II equipment with ‘floating circuits’ that is considered to be safe for direct connection with the heart. There are extremely low leakage currents (0.05mA for Class I CF and 0.01mA for Class II CF).

    • This question is part of the following fields:

      • Clinical Measurement
      22.4
      Seconds
  • Question 9 - Which one of the following patients presenting for elective surgery has an American...

    Correct

    • Which one of the following patients presenting for elective surgery has an American Society of Anaesthesiologists (ASA) preoperative physical status grading of III?

      Your Answer: A 50-year old man with a BMI of 41 with a reduced exercise tolerance

      Explanation:

      The ASA physical status classification system is a system for assessing the fitness of patients before surgery. It was last updated in October 2014.

      ASA I A normal healthy patient
      ASA II A patient with mild systemic disease
      ASA III A patient with severe systemic disease
      ASA IV A patient with severe systemic disease that is a constant threat to life
      ASA V A moribund patient who is not expected to survive without the operation
      ASA VI A declared brain-dead patient whose organs are being removed for donor purposes

      A 20-year old woman who is 39-weeks pregnant with no other medical conditions – ASA II

      A 35-year-old man with a BMI of 29 with a good exercise tolerance who smokes-ASA II

      A 50-year old man with a BMI of 41 with a reduced exercise tolerance -ASA III

      A 65-year old woman with a BMI of 34 with treated hypertension with no functional limitations-ASA II

      A 73-year old man who has had a TIA ten-weeks ago but has a good exercise tolerance and is a non-smoker-ASA IV.

    • This question is part of the following fields:

      • Clinical Measurement
      40.4
      Seconds
  • Question 10 - If the speed of an ultrasound in soft tissue is 1540 meters per...

    Correct

    • If the speed of an ultrasound in soft tissue is 1540 meters per second, what is the estimated wavelength produced if the frequency of a generated ultrasound is 10 megahertz?

      Your Answer: 0.15 millimetre

      Explanation:

      Wavelength can be computed as follows:

      Wavelength = velocity/frequency

      In the given problem, the values stated are:

      Frequency = 10 x 10^6
      Velocity = 1540 meters per second

      Wavelength = 1540/(10×10^6)
      Wavelength = 1540/10,000,000 meters
      Wavelength = 0.15 millimetres.

    • This question is part of the following fields:

      • Clinical Measurement
      39
      Seconds
  • Question 11 - Which of the following is a correctly stated fundamental (base) SI unit? ...

    Correct

    • Which of the following is a correctly stated fundamental (base) SI unit?

      Your Answer: A metre is the unit of length

      Explanation:

      The international system of units, or system international d’unites (SI) is a collection of measurements derived from expanding the metric system.

      There are seven base units, which are:

      Metre (m): a unit of length
      Second (s): a unit of time
      Kilogram (kg): a unit of mass
      Ampere (A): a unit of electrical current
      Kelvin (K): a unit of thermodynamic temperature
      Candela (cd): a unit of luminous intensity
      Mole (mol): a unit of substance.

    • This question is part of the following fields:

      • Clinical Measurement
      24.5
      Seconds
  • Question 12 - The statement that best describes temperature management is: ...

    Incorrect

    • The statement that best describes temperature management is:

      Your Answer: Thermocouples use the principle that resistance in metals show a linear increase with temperature

      Correct Answer: Gauge thermometers use coils of different metals with different co-efficients of expansion which either tighten or relax with changes in temperature

      Explanation:

      There are different types of temperature measurement. These include:

      Thermistor – this is a type of semiconductor, meaning they have greater resistance than conducting materials, but lower resistance than insulating materials. There are small beads of semiconductor material (e.g. metal oxide) which are incorporated into a Wheatstone bridge circuit. As the temperature increases, the resistance of the bead decreases exponentially

      Thermocouple – Two different metals make up a thermocouple. Generally, in the form of two wires twisted, welded, or crimped together. Temperature is sensed by measuring the voltage. A potential difference is created that is proportional to the temperature at the junction (Seebeck effect)

      Platinum resistance thermometers (PTR) – uses platinum for determining the temperature. The principle used is that the resistance of platinum changes with the change of temperature. The thermometer measures the temperature over the range of 200°C to1200°C. Resistance in metals show a linear increase with temperature

      Tympanic thermometers – uses infrared radiation which is emitted by all living beings. It analyses the intensity and wavelength and then transduces the heat energy into a measurable electrical output

      Gauge/dial thermometers – Uses coils of different metals with different co-efficient of expansion. These either tighten or relax with changes in temperature, moving a lever on a calibrated dial.

    • This question is part of the following fields:

      • Clinical Measurement
      37.1
      Seconds
  • Question 13 - A 20-year-old female presents to the emergency department. She complains of increased shortness...

    Correct

    • A 20-year-old female presents to the emergency department. She complains of increased shortness of breath and wheezing over the last 48 hours. On examination, she is found to have tachycardia, tachypnoea, and oxygen saturation at 91% on air. She admits to a previous medical history of asthma, diagnosed 4 years ago. She requires further investigations for diagnosis. Which of the following is true about the assessment of a patient with symptomatic asthma?

      Your Answer: Oxygen saturations of 91% on air would be an indication for performing arterial blood gases

      Explanation:

      A patient presenting with symptomatic asthma should be assessed for severity to determine appropriate management options. Indications of acute severe asthma are:

      Peak expiratory flow rate (PEFR): 33-50% best/predicted
      Respiratory rate: ‰¥25/min
      Heart rate: ‰¥110/min
      Inability to finish a complete sentence in a single breath.

      Oxygen saturation should be measured. Any measurement of an oxygen saturation of 92% or less, either on air or on oxygen, indicates severe, life threatening asthma, and requires an arterial blood gas (ABG) to detect normo- or hypercarbia.

      A chest x-ray would not be routine as it will not provide any relevant information. It is only required in specific cases, including:
      Diagnosis of a subcutaneous emphysema
      Indications of a unilateral pneumothorax
      Indications of a lobar collapse of consolidation
      Treatment-resistance life-threatening asthma
      If mechanical ventilation is indicated

      A peak expiratory flow rate (PEFR) can provide relevant information to help distinguish between acute, moderate, severe and life threatening asthma. However, it is not necessary as other parameters exist that can also help make the same distinction.

      An ECG is indicated in this case as the patient has tachycardia and tachypnoea which are indicative of acute severe asthma. The ECG would indicate if arrhythmia is also present which would suggest life-threatening asthma.

    • This question is part of the following fields:

      • Clinical Measurement
      92.6
      Seconds
  • Question 14 - A 23-year-old man, has just undergone surgery under general anaesthesia. He has experienced...

    Incorrect

    • A 23-year-old man, has just undergone surgery under general anaesthesia. He has experienced a severe reaction to the anaesthetic agent resulting in malignant hyperthermia (MH) for which he has been referred for treatment. What investigation can be conducted to determine a patient's susceptibility to malignant hyperthermia?

      Your Answer: In vitro muscle contraction test using ryanodine

      Correct Answer: In vitro muscle contraction test using caffeine

      Explanation:

      Malignant hyperthermia (MH) is a autosomal dominant inherited medical condition which predisposes affected individuals to a clinical syndrome of hypermetabolism which involves abnormal ryanodine receptors in skeletal muscle causing a deregulation of calcium in muscle.

      It is a life threatening condition requiring immediate medical intervention. It often lies dormant until triggered in susceptible individuals mostly by volatile inhaled anaesthetic agents and succinylcholine which is a muscle relaxant.

      The signs and symptoms of MH are related to this hypermetabolism, which includes an increase in carbon dioxide production, metabolic and respiratory acidosis, accelerated oxygen consumption, heat production, activation of the sympathetic nervous system, hyperkalaemia, disseminated intravascular coagulation (DIC), and multiple organ dysfunction and failure.

      Early signs of MH to look out for in patients includes an uptick in end-tidal carbon dioxide (even with increasing minute ventilation), tachycardia, muscle rigidity, tachypnoea, and hyperkalaemia. Later signs include fever, myoglobinuria, and multiple organ failure.

      In vitro muscle contracture test (IVCT) is the standard for determining individual susceptibility to MH. It is conducted by measuring the force of muscle contraction after exposing the patient’s muscle sample to halothane and caffeine., the sample is normally taken from the vastus medialis or lateralis under regional anaesthesia.

    • This question is part of the following fields:

      • Clinical Measurement
      31.7
      Seconds
  • Question 15 - Which of the following statements about closing capacity is true? ...

    Correct

    • Which of the following statements about closing capacity is true?

      Your Answer: It is less than the functional residual capacity in a 30-year-old

      Explanation:

      Closing capacity refers to volume of gas within the lungs at which the conducting small airways begin to close, that is, the point during expiration when small airways close.

      It is calculated mathematically as:

      Closing capacity = Closing volume (CV) + Residual volume (RV)

      Functional residual capacity (FRC) is the volume of gas still present within the lungs post expiration.

      Closing capacity is lower than the functional residual capacity in younger adults, but begins to rise to eventually equal, and then exceed it with increasing age (at about middle age), increasing intrabdominal pressure, decreasing blood flow in the pulmonary system and parenchymal disease within the pulmonary system.

    • This question is part of the following fields:

      • Clinical Measurement
      61.7
      Seconds
  • Question 16 - A 50-year old man for septoplasty has a BMI of 32kg/m2 and neck...

    Incorrect

    • A 50-year old man for septoplasty has a BMI of 32kg/m2 and neck circumference of 44 cm. He is troubled by intermittent nasal obstruction which causes his partner sleeps in a separate bedroom because of snoring. He currently on ramipril for hypertension. Which of the following best approximates to his STOP-BANG score from the information above?

      Your Answer: 4

      Correct Answer: 5

      Explanation:

      The STOP-BANG questionnaire is used to screen patients for obstructive sleep apnoea (OSA).

      The scoring system assigns one point for each feature.

      S: Snoring (louder than talking or loud enough to be heard through closed doors)
      T: Feeling tired, fatigued, or sleepy during daytime
      O: Observed apnoeas during sleep
      P: Hypertension
      B: BMI more than 35 kg/m2
      A: Age 50-years of age or greater
      N: Neck circumference (male 17 inches / 43cm or greater and female 16 inches / 41 or greater)
      G: Gender: Male

      Our patient has a score of 5 ( O, P, A, N, G)

      The score helps clinicians stratify patients for unrecognized OSA and target appropriate clinical management. It can also help triage patients for further investigation. A STOP-BANG score of 5-8 will identify patients with high probability of moderate to severe OSA in the surgical population.

    • This question is part of the following fields:

      • Clinical Measurement
      26.4
      Seconds
  • Question 17 - An 84-year-old woman has a fall. She fractures the neck of her femur...

    Correct

    • An 84-year-old woman has a fall. She fractures the neck of her femur and requires emergency surgery. On history and examination, she appears to also have a possible heart failure for which an echocardiogram is scheduled. Her measurements are: End-diastolic volume: 40mL (70-240), End-systolic volume: 30mL (16-140). Calculate her approximate ejection fraction.

      Your Answer: 25%

      Explanation:

      An echocardiogram provides real-time visualisation of cardiac structures. The ejection fraction (EF) is normally measured using this system.

      The ejection fraction (EF) can be deduced mathematically if the patient’s end-diastolic volume (EDV), end-systolic volume (ESV) and stroke volume (SV) are known, as:

      SV = EDV – ESV, and

      EF = SV/EDV x 100

      The normal range for EF is >55-70%.

      For this patient,

      SV= 40 – 30 = 10 mL, therefore

      EF = 10/40 x 100 = 25%.

    • This question is part of the following fields:

      • Clinical Measurement
      27
      Seconds
  • Question 18 - Which of the following is true about the bispectral index (BIS)? ...

    Correct

    • Which of the following is true about the bispectral index (BIS)?

      Your Answer: Sevoflurane lowers BIS more than ketamine

      Explanation:

      The bispectral index (BIS) monitors works to determine the level of consciousness of a patient by processing electroencephalographic (EEG) signals to obtain a value between 0 and 100, where 0 reflects no brain activity, and 100 reflects a patient is completely awake.

      The general meaning of BIS values are:

      >95: Patient is in an awake state.
      65-85: Patient is in a sedated state.
      40-65: Patient is in a state that is optimal for general surgery.
      <40: Patient is in a deep hypnotic state

      It is important in measuring the depths of anaesthesia to prevent haemodynamic changes or patient awareness during surgery.

      The nature of anaesthetic agent used is a determinant factor in resultant BIS values. Intravenous agents, such as propofol, thiopental and midazolam, result in a deeper hypnotic state, whilst inhalation agents have a lesser hypnotic effect at the same BIS values. Certain agents result in inaccurate BIS values such as ketamine and nitrous oxide (NO). These two agents appear to increase the BIS value, whilst putting the patient in a deeper hypnotic state, and should therefore not be used with BIS monitoring.

      Hypothermia also affects the BIS value as it causes a 1.12 per °C decrease in body temperature.

    • This question is part of the following fields:

      • Clinical Measurement
      18.1
      Seconds
  • Question 19 - Which of the following statements about the central venous pressure (CVP) waveform is...

    Correct

    • Which of the following statements about the central venous pressure (CVP) waveform is true?

      Your Answer: Third degree heart block causes canon A waves

      Explanation:

      The central venous pressure (CVP) waveform depicts changes of pressure within the right atrium. Different parts of the waveform are:

      A wave: which represents atrial contraction. It is synonymous with the P wave seen during an ECG. It is often eliminated in the presence of atrial fibrillation, and increased tricuspid stenosis, pulmonary stenosis and pulmonary hypertension.

      C wave: which represents right ventricle contraction at the point where the tricuspid valve bulges into the right atrium. It is synonymous with the QRS complex seen on ECG.

      X descent: which represents relaxation of the atrial diastole and a decrease in atrial pressure, due to the downward movement of the right ventricle as it contracts. It is synonymous with the point before the T wave on ECG.

      V wave: which represents an increase in atrial pressure just before the opening of the tricuspid valve. It is synonymous with the point after the T wave on ECG. It is increased in the background of a tricuspid regurgitation.

      Y descent: which represents the emptying of the atrium as the tricuspid valve opens to allow for blood flow into the ventricle in early diastole.

      Canon waves: which refer to large waves present on the trace that do not correspond to the A, V or C waves. They usually occur in a background of complete heart blocks or junctional arrythmias.

    • This question is part of the following fields:

      • Clinical Measurement
      14
      Seconds
  • Question 20 - A pulmonary function tests results are: (Measurement, Predicted result, Test result). Forced vital...

    Correct

    • A pulmonary function tests results are: (Measurement, Predicted result, Test result). Forced vital capacity (FVC) (btps): 3.85, 2.36 Forced expiratory volume in 1 second (FEV1) (btps): 3.34, 0.97. FEV1/FVC ratio % (btps): 85.1, 39.9. Peak expiratory flow (PEF) (L/second): 7.33, 2.11. Maximum voluntary ventilation (MVV) (L/minute): 116, 44.4. What does this indicate?

      Your Answer: Moderate restrictive and severe obstructive picture

      Explanation:

      Severity of a reduction in restrictive defect (%FVC) or obstructive defect (V1/FVC) predicted are classified as follows:

      Mild 70-80%
      Moderate 60-69%
      Moderately severe 50-59%
      Severe 35-49%
      Very severe <35%

      This patient has a mixed deficit with a severe obstructive deficit as V1/FVC predicted is 46.9% and a moderate restrictive deficit as %FVC of predicted is 61.3

      FEV1/FVC ratio 80% < predicted and VC < 80% = mixed picture.

      FEV1/FVC ratio 80% < predicted and VC > 80% = obstructive picture.

      FEV1/FVC ratio 80% > predicted and VC > 80% = normal picture.

      FEV1/FVC ratio 80% > predicted and VC < 80% predicted= restrictive picture.

    • This question is part of the following fields:

      • Clinical Measurement
      71.2
      Seconds
  • Question 21 - A 49-year-old woman is admitted to hospital. She is scheduled for surgery and...

    Incorrect

    • A 49-year-old woman is admitted to hospital. She is scheduled for surgery and is undergoing preoperative assessment. As part of the preoperative assessment, her functional capacity is estimated. At 50kg in weight, she is able to cycle along a flat surface at a speed of 10-14 miles/hour (8 metabolic equivalents or METs). Provide the best estimated value of oxygen consumption (VO2) for eight METs.

      Your Answer:

      Correct Answer: 1400 mL/minute

      Explanation:

      Oxygen consumption (VO2) refers to the optimal amount of oxygen used by the body during exercise.

      It is calculated mathematically by:

      VO2 = 3.5 x 50 x 8 = 1400 mL/kg/minute

      where,

      1 MET = 3.5 mL O2/kg/minute is utilized by the body.

      Note:

      1 MET Eating
      Dressing
      Use toilet
      Walking slowly on level ground at 2-3 mph
      2 METs Playing a musical instrument
      Walking indoors around house
      Light housework
      4 METs Climbing a flight of stairs
      Walking up hill
      Running a short distance
      Heavy housework, scrubbing floors, moving heavy furniture
      Walking on level ground at 4 mph
      Recreational activity, e.g. golf, bowling, dancing, tennis
      6 METs Leisurely swimming
      Leisurely cycling along the flat (8-10 mph)
      8 METs Cycling along the flat (10-14 mph)
      Basketball game
      10 METs Moderate to hard swimming
      Competitive football
      Fast cycling (14-16 mph).

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 22 - The following are results of some pulmonary function tests: (Measurement - Predicted result...

    Incorrect

    • The following are results of some pulmonary function tests: (Measurement - Predicted result - Test result). Forced vital capacity (FVC) (btps): 3.21, - 1.94. Forced expiratory volume in 1 second (FEV1) (btps): 2.77, 1.82. FEV1/FVC ratio % (btps): 81.9, 93.5. Peak expiratory flow (PEF) (L/second): 6.55, 3.62. Maximum voluntary ventilation (MVV) (L/minute): 103, 87.1 Which statement applies to the results?

      Your Answer:

      Correct Answer: The patient has a moderate restrictive pulmonary defect

      Explanation:

      Severity of a reduction in restrictive defect (%FVC) or obstructive defect (V1/FVC) predicted are classified as follows:

      Mild 70-80%
      Moderate 60-69%
      Moderately severe 50-59%
      Severe 35-49%
      Very severe <35%

      This patient has a %FVC predicted of 60.4% and this corresponds to a moderate restrictive deficit. V1/FVC ratio is 93.5%.

      FEV1/FVC ratio 80% < predicted and VC < 80% = mixed picture.

      FEV1/FVC ratio 80% < predicted and VC > 80% = obstructive picture.

      FEV1/FVC ratio 80% > predicted and VC > 80% = normal picture.

      FEV1/FVC ratio 80% > predicted and VC < 80% predicted= restrictive picture.

      The integrity of the alveolar-capillary barrier is measured by carbon monoxide transfer factor (TLCO) and carbon monoxide transfer coefficient (KCO). These values are seen to be reduced in emphysema, interstitial lung diseases and in pulmonary vascular pathology. However, the KCO (as % predicted) is high in extrapulmonary restriction (pleural, chest wall and respiratory neuromuscular disease), and in loss of lung units provided the structure of the lung remaining is normal. The KCO distinguishes extrapulmonary (high KCO) causes of 'restriction' from intrapulmonary causes (low KCO).

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 23 - Which of the following lung parameters can be measured directly using spirometry? ...

    Incorrect

    • Which of the following lung parameters can be measured directly using spirometry?

      Your Answer:

      Correct Answer: Vital capacity

      Explanation:

      Spirometry measures the total volume of air that can be forced out in one maximum breath, that is the total lung capacity (TLC), to maximal expiration, that is the residual volume (RV).

      It is conducted using a spirometer which is capable of measuring lung volumes using techniques of dilution.

      During spirometry, the following measurements can be determined:
      Forced vital capacity (FVC)/vital capacity (VC): The maximum volume of air exhaled in one single forced breathe.
      Forced expiratory volume in one second (FEV1)
      FEV1/FVC ratio
      Peak expiratory flow (PEF): the maximum amount of air flow exhaled in one blow.
      Forced expiratory flow (mid expiratory flow): the flow at 25%, 50% and 75% of FVC
      Inspiratory vital capacity (IVC): The maximum volume of air inhaled after a full total expiration.

      Anatomical dead space is measured using a single breath nitrogen washout called the Fowler’s method.

      Residual volume and total lung capacity are both measured using the body plethysmograph or helium dilution

      The functional residual capacity is usually measured using a nitrogen washout or the helium dilution technique.

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 24 - A 77-year-old man is admitted to hospital for colorectal surgery. He is scheduled...

    Incorrect

    • A 77-year-old man is admitted to hospital for colorectal surgery. He is scheduled to undergo a preoperative assessment, which includes cardiopulmonary exercise test (CPX). During the CPX, his maximum oxygen consumption (VO2 max) is determined to be 2,100 mL/minute. His weight is measured to be 100 kg. Calculate the metabolic equivalent (MET) that is the best estimate for his VO2 max.

      Your Answer:

      Correct Answer: 6 METs

      Explanation:

      Metabolic equivalent (MET) measures the energy expenditure of an individual.

      It is calculated mathematically by:

      MET = (VO2 max/weight)/3.5 = 21/3.5 = 6 METs

      Where 1 MET = 3.5 mL O2/kg/minute is utilized by the body.

      Note:

      1 MET Eating
      Dressing
      Use toilet
      Walking slowly on level ground at 2-3 mph
      2 METs Playing a musical instrument
      Walking indoors around house
      Light housework
      4 METs Climbing a flight of stairs
      Walking up hill
      Running a short distance
      Heavy housework, scrubbing floors, moving heavy furniture
      Walking on level ground at 4 mph
      Recreational activity, e.g. golf, bowling, dancing, tennis
      6 METs Leisurely swimming
      Leisurely cycling along the flat (8-10 mph)
      8 METs Cycling along the flat (10-14 mph)
      Basketball game
      10 METs Moderate to hard swimming
      Competitive football
      Fast cycling (14-16 mph).

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 25 - The following statements are about capnography. Which of them is true? ...

    Incorrect

    • The following statements are about capnography. Which of them is true?

      Your Answer:

      Correct Answer: Collision broadening is due to presence of other polyatomic molecules

      Explanation:

      Capnography is the non-invasive measurement and pictorial display of inhaled and exhaled carbon dioxide (CO2) partial pressure.

      It is depicted graphically as the concentration of CO2 over time.

      It is used in disease diagnosis, determining disease severity, assessing response to treatment and is the best method to for indicating when an endotracheal tube is placed in the trachea after intubation.

      The wavelength of IR light usually absorbed by nitrous oxide is between 4.4-4.6μm (very close to that of CO2). Its absorption of wavelengths at 3.9 μm is much weaker. It causes a measurable deficit of 0.1% for every 10% of nitrous oxide. The maximal wavelength of infrared (IR) light absorbed by carbon monoxide is 4.7 μm. The volatile agents have strong absorption bands at 3.3 μm and throughout the ranges 8-12 μm.

      IR light is not absorbed by oxygen (O2), but O2 and CO2 molecules are constantly colliding which interrupts the absorption of IR light by CO2. This increases the band of absorption, that is the Collison or pressure broadening). An oxygen percentage of 95 will result in a 0.5 percentage fall in CO2 measure.

      IR light is also absorbed by water vapour which will result in an overlap of the absorption band, collision broadening and a dilution of partial pressure. This is why water trap and water permeable tubing is recommended for use as it reduces measurement inaccuracies.

      The use of multi-gas analysers of modern gases also help reduce the effects of collision broadening.

      Beer’s law is also applied in this system as an increase in the concentrations of CO2 causes a decrease in the amount of IR able to pass through the gas. This IR light is what generated the signal that is analysed for display.

      The capnograph can indicate oesophageal intubation, but cannot determine if it is endotracheal or endobronchial. For this, auscultation is used.

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 26 - Regarding sine wave damping, which one would approach equilibrium the fastest at zero...

    Incorrect

    • Regarding sine wave damping, which one would approach equilibrium the fastest at zero amplitude, without overshoot?

      Your Answer:

      Correct Answer: Critical damping

      Explanation:

      A damped sine wave is a smooth, periodic oscillation with an amplitude that approaches zero as time goes to infinity. In other words, the wave gets flatter as the x-values become larger.

      Critical damping is defined as the threshold between overdamping and underdamping. In the case of critical damping, the oscillator returns to the equilibrium position as quickly as possible, without oscillating, and passes it once at most.

      In overdamping, the system moves slowly towards the equilibrium. An underdamped system moves quickly to equilibrium, but will oscillate about the equilibrium point as it does so.

      Optimal damping has a damping coefficient of around 0.64-0.7. It maximizes frequency response, minimizes overshoot of oscillations, and minimizes phase and amplitude distortion.

      In an undamped system, the amplitude of the waves that are being generated remain unchanged and constant over time.

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 27 - With regards to devices for temperature management, all of these are used EXCEPT:...

    Incorrect

    • With regards to devices for temperature management, all of these are used EXCEPT:

      Your Answer:

      Correct Answer: Thermistors use the resistance of a semiconductor bead which increases exponentially as the temperature increases

      Explanation:

      There are different types of temperature measurement. These include:

      Thermistor – this is a type of semiconductor, meaning they have greater resistance than conducting materials, but lower resistance than insulating materials. There are small beads of semiconductor material (e.g. metal oxide) which are incorporated into a Wheatstone bridge circuit. As the temperature increases, the resistance of the bead decreases exponentially

      Thermocouple – Two different metals make up a thermocouple. Generally, in the form of two wires twisted, welded, or crimped together. Temperature is sensed by measuring the voltage. A potential difference is created that is proportional to the temperature at the junction (Seebeck effect)

      Platinum resistance thermometers (PTR) – uses platinum for determining the temperature. The principle used is that the resistance of platinum changes with the change of temperature. The thermometer measures the temperature over the range of 200°C to1200°C. Resistance in metals show a linear increase with temperature

      Tympanic thermometers – uses infrared radiation which is emitted by all living beings. It analyses the intensity and wavelength and then transduces the heat energy into a measurable electrical output

      Gauge/dial thermometers – Uses coils of different metals with different co-efficient of expansion. These either tighten or relax with changes in temperature, moving a lever on a calibrated dial.

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 28 - A 64-year-old man is admitted to the critical care unit. He has a...

    Incorrect

    • A 64-year-old man is admitted to the critical care unit. He has a recent medical history of faecal peritonitis for which a laparotomy was performed. His vitals have been monitored using an invasive pulmonary artery flotation catheter. His vital readings are: Temperature: 38.1°C. Blood pressure: 79/51 mmHg (mean 58 mmHg), Pulmonary artery pressure: 19/6 mmHg (mean 10 mmHg). Pulmonary capillary occlusion pressure: 5 mmHg, Central venous pressure: 12 mmHg, Cardiac output: 5 L/min, Mixed venous oxygen saturation: 82%. Calculate his approximate pulmonary vascular resistance. Note: A correction factor of 80 is require to convert mmHg to dynes·s·cm-5

      Your Answer:

      Correct Answer: 80 dynes·s·cm-5

      Explanation:

      Pulmonary vascular resistance (PVR) refers to the resistance to blood flow to the left atrium from the pulmonary artery.
      It is derived mathematically by:

      PVR = MPAP – PCWP
      CO
      where,
      MPAP: Mean pulmonary artery pressure
      PCWP: Pulmonary capillary occlusion pressure
      CO: Cardiac output

      For this patient:
      PVR = 10 – 5 = 1mmHg
      5

      Remember, multiply by correction factor 80 to change units:

      PVR = 1mmHg x 80 = 80 dynes·s·cm-5

      Normal values range between 20-130 dynes·s·cm-5.

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 29 - A 28-year-old man is admitted to the critical care unit. He has been...

    Incorrect

    • A 28-year-old man is admitted to the critical care unit. He has been diagnosed with adult respiratory distress syndrome and is being ventilated. His haemodynamic condition is improved using a pulmonary artery flotation. His readings are listed below: Haemoglobin concentration: 10 g/dL, Mixed venous oxygen saturation: 70%, Mixed venous oxygen tensions (PvO2): 50 mmHg. Estimate his mixed venous oxygen content (mL/100mL).

      Your Answer:

      Correct Answer: 9.5

      Explanation:

      Mixed venous oxygen content (CvO2) is the oxygen concentration in 100mL of mixed venous blood taken from the pulmonary artery. It is usually 12-17 mL/dL (70-75%). It is represented mathematically as:

      CvO2 = (1.34 x Hgb x SvO2 x 0.01) + (0.003 x PvO2)

      Where,

      1.34 = Huffner’s constant
      Hgb = Haemoglobin level (g/dL)
      SvO2 = % oxyhaemoglobin saturation of mixed venous blood
      PvO2 = 0.0225 = mL of O2 dissolved per 100mL plasma per kPa, or 0.003 mL per mmHg

      Therefore,

      CvO2 = (1.34 x 10 x 70 x 0.01) + (0.003 x 50)

      CvO2 = 9.38 + 0.15 = 9.53 mL/100mL.

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 30 - Systemic vascular resistance (multiplied by 80) to produce the units of dynes.s.cm-5 is...

    Incorrect

    • Systemic vascular resistance (multiplied by 80) to produce the units of dynes.s.cm-5 is represented by?

      Your Answer:

      Correct Answer: Mean arterial pressure (MAP) - central venous pressure (CVP)/cardiac output (CO)

      Explanation:

      Systemic vascular resistance (SVR) is a derived value based on:

      SVR = (MAP-CVP)/CO x 80

      = (60 -10)/5 x 80 = 800 dynes.s.cm-5

      A correction factor of 80 is needed in converting mmHg to dynes.s.cm-5
      Normal values is between 700 -1600 dynes.s.cm-5

      Pulmonary resistance (PVR) = (MPAP-PCWP)/CO x 80

      = (10 – 5)/5 x 80 = 80 dynes.s.cm-5

      To account for body size, cardiac index (CI) can be used instead of CO. CI = CO/body surface area (m2) or mL/minute/m2.
      N/B: either MAP and CVP, or MPAP and PCWP are used in calculation to get dynes.s.cm-5.

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 31 - An arterial pressure transducer is supposedly in direct correlation to change, thus it...

    Incorrect

    • An arterial pressure transducer is supposedly in direct correlation to change, thus it is dependent on zero gradient drift and zero offset. Which of the following values will best compensate for the gradient drift?

      Your Answer:

      Correct Answer: 0 mmHg and 200 mmHg

      Explanation:

      Since an arterial pressure transducer, and every other measuring apparatus, is prone to errors due to offset and gradient drifts, regular calibration is required to maintain accuracy of the instrument. The two-point calibration pressure values of 0 mmHg and 200 mmHg are within the physiologic range and can best compensate for the gradient drift.

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 32 - A 50-year-old man is admitted in hospital. Over four hours, he produces 240...

    Incorrect

    • A 50-year-old man is admitted in hospital. Over four hours, he produces 240 mL of urine and has a plasma creatinine concentration is 10 mcg/mL. The normal concentration of creatinine in urine is 1.25 mg/mL. Calculate his approximate creatinine clearance.

      Your Answer:

      Correct Answer: 125 ml/minute

      Explanation:

      Creatinine clearance is a test used to approximate the glomerular filtration rate (GFR) as an assessment of kidney function.

      Creatinine is formed during the breakdown of dietary sources of meat and skeletal muscle. It is secreted at a consistent concentration and pace into the body’s circulation, and is easily filtered across the glomerulus without being reabsorbed or metabolized by the kidney.

      It is represented mathematically as:
      Creatinine clearance (CL) = U x V/P
      where,
      U: Urinary creatinine concentration (mg/mL)
      V: Volume of urine (mL/min)
      P: Plasma creatinine concentration (mg/mL)

      Therefore, in this case:
      CL: 1.25 x 1 = 125mL/min.

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 33 - Which of the following can be measured directly using spirometry? ...

    Incorrect

    • Which of the following can be measured directly using spirometry?

      Your Answer:

      Correct Answer: Vital capacity

      Explanation:

      Spirometry measures the total volume of air that can be forced out in one maximum breath, that is the total lung capacity (TLC), to maximal expiration, that is the residual volume (RV).

      It is conducted using a spirometer which is capable of measuring lung volumes using techniques of dilution.

      During spirometry, the following measurements can be determined:
      Forced vital capacity (FVC)/vital capacity (VC): The maximum volume of air exhaled in one single forced breathe.
      Forced expiratory volume in one second (FEV1)
      FEV1/FVC ratio
      Peak expiratory flow (PEF): the maximum amount of air flow exhaled in one blow.
      Forced expiratory flow (mid expiratory flow): the flow at 25%, 50% and 75% of FVC
      Inspiratory vital capacity (IVC): The maximum volume of air inhaled after a full total expiration.

      Anatomical dead space is measured using a single breath nitrogen washout called the Fowler’s method.

      Residual volume and total lung capacity are both measured using the body plethysmograph or helium dilution

      The functional residual capacity is usually measured using a nitrogen washout or the helium dilution technique.

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 34 - Which of the following is a true statement about invasive arterial pressure monitoring?...

    Incorrect

    • Which of the following is a true statement about invasive arterial pressure monitoring?

      Your Answer:

      Correct Answer: Increased resonance elevates the systolic and lower the diastolic pressures

      Explanation:

      The arterial cannula inserted should have parallel walls in order to reduce the risk of interruption of blood flow to distal limbs.

      It is essential that the monitor used to display the arterial pressure waves has a frequency capacity of 0.5-40Hz. This is because the pressure waves are a combination of different sine waves of varying frequencies and amplitudes.

      The diameter of the catheter is directly proportional to the natural frequency which is the frequency at which the system responsible for monitoring the waves resonates and amplifies the signals. This should be at least ten fold in comparison to the fundamental frequency. The diameter of the catheter is also inversely proportional to the square root of the system compliance, the tubing length and the fluid density within the system.

      The presence of an air bubble, a clot or an easily malleable diaphragm and tube can result in wave damping. Increased damping will cause a reduction in the systolic pressure, and an increase in diastolic pressure. The maximum damping value of an appropriate monitoring system would be 0.64.

      A rigid, non-malleable diaphragm and tubing can cause a resonance within the system. This resonance will result in an increase in the systolic pressure and a reduction in the diastolic pressure.

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 35 - Blood pressure monitoring is a requirement for in-patient care. Different factors can result...

    Incorrect

    • Blood pressure monitoring is a requirement for in-patient care. Different factors can result in an inaccurate blood pressure reading, including the damping of an arterial waveform. How does a damped arterial waveform affect blood pressure measurements?

      Your Answer:

      Correct Answer: The systolic pressure is lower and the diastolic pressure higher with the same mean

      Explanation:

      Damping is the reduction of energy in a system achieved by reducing the amplitude of oscillations. It is necessary to some degree to prevent wave overshoots.

      Critical damping usually causes the system to be slow, so optimal damping is normally applied to provide a balance between speed and distortion.

      Damping can cause errors if excessive (overdamping) or inadequate (Underdamping). The amount of damping in a system can be determined using the damping coefficient (D), where:

      Undamped: 0
      Critically damped: 1
      Optimally damped: 0.64

      An overdamped system will cause an artificial decrease in the systolic blood pressure, and an artificial increase in the diastolic blood pressure.

      An underdamped system will cause an artificial increase in systolic blood pressure and an artificial decrease in diastolic blood pressure.

      Damping can be caused by a number of factors affecting different parts of the system, including:

      The tubing/cannula: The presence of air bubbles, increased blood viscosity or formation of blood clots.
      The diaphragm/tubing: Increased malleability/compliance
      The tubing: Presence of kinks, narrowing or too many ports of injection.

      The answer here is a damped system will have a low systolic pressure, a high diastolic pressure with a normal mean pressure.

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 36 - Which of the following options will cause an artificial increase in pulse oximeter...

    Incorrect

    • Which of the following options will cause an artificial increase in pulse oximeter (SpO2) readings?

      Your Answer:

      Correct Answer: Heavy smoker

      Explanation:

      A pulse oximeter is a piece of medical equipment used as a non-invasive method of measuring the oxygen saturation of blood.

      It works by measuring the ratio of absorption of red and infrared light in a section of blood flow, as red light is largely absorbed by deoxygenated blood, and infrared light is largely absorbed by oxygenated blood.

      Pulse oximetry relies on photoplethysmography (PPG) waveforms. The oximeter has 2 sides, with different functions. One side houses light-emitting diodes which are responsible for transmitting 2 light wavelengths, 660nm for red light and 940nm for near infrared light. The other side is a photodetector. The light emitted travels through the body and the amount that is not absorbed is measured by the photodetector.

      Smokers often have increased levels of carboxy haemoglobin (COHb). This leads to artificial increases in pulse oximeter readings as it is unable to differentiate between COHb and oxyhaemoglobin (O2HB) as they both absorb red light at 660nm. Every 1% increase of circulating carboxyhaemoglobin, results in a correlative 1% increase in oximeter readings.

      Prilocaine toxicity will cause an artificial decrease in oximeter readings. This is because prilocaine metabolites cause methemoglobinemia (MetHB), which are dysfunctional haemoglobins unable to properly transport oxygen. In this case, a laboratory multiwavelength co-oximeter is recommended for a more accurate reading.

      Anaemia will not affect oximeter readings as long as haemoglobins in the blood are normal.

      Sickle cell disease does not affect oximeter readings despite its ability to cause hypoxia and shift the oxygen dissociation curve to the right.

      Brown-red fingernail polish will cause an underestimation of pulse oximeter readings.

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 37 - Which of these statements is true about spirometry? ...

    Incorrect

    • Which of these statements is true about spirometry?

      Your Answer:

      Correct Answer: A capacity is the sum of two or more volumes

      Explanation:

      Functional residual capacity (FRC) is 1.7 to 3.5L/kg

      A capacity is the sum of two or more volumes. The total lung capacity (TLC) is total sum of the volume of gas present in all lung compartments upon maximum inspiration. It is represented mathematically as:

      Total lung capacity (TLC) = Vital capacity (VC) + Residual volume (RV)

      The residual volume (RV) is the volume of gas still present within the lung post maximum exhalation. It cannot be measured by spirometry, but can be using a body plethysmograph and also with the helium dilution technique.

      Closing capacity (CC) is the volume of gas within the lungs at which small airways close upon expiration. It increases with age and is especially important when it surpasses the FRC as it causes changes in ventilation/perfusion mismatch and hypoxia.
      In the supine position, a patient with a normal body mass index and no history of lung pathology, the CC equals the FRC at approximately 44, and at approximately 66 at standing position.

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 38 - The following haemodynamic data is available from a patient with pulmonary artery catheter...

    Incorrect

    • The following haemodynamic data is available from a patient with pulmonary artery catheter inserted: Pulse rate - 100 beats per minute, Blood pressure - 120/70mmHg, Mean central venous pressure (MCVP) - 10mmHg, Right ventricular pressure (RVP) - 30/4 mmHg, Mean pulmonary artery wedge pressure (MPAWP) - 12mmHg. Which value best approximates the patient's coronary perfusion pressure?

      Your Answer:

      Correct Answer: 58mmHg

      Explanation:

      Coronary perfusion pressure(CPP), the difference between aortic diastolic pressure (Pdiastolic) and the left ventricular end-diastolic pressure (LVEDP), is mainly determined by the formula:

      CPP = Pdiastolic -LVEDP
      where
      Pdiastolic is the lowest pressure in the aorta before left ventricular ejection and
      LVEDP is measured directly during a cardiac catheterisation or indirectly using a pulmonary artery catheter. The pulmonary artery occlusion or wedge pressure approximates best with LVEDP.

      Using this patient’s haemodynamic data:

      CPP = Pdiastolic – MPAWP
      COO = 70 – 12 = 58mmHg.

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 39 - The diaphragm is a muscle that is relatively resistant to non-depolarizing neuromuscular blockade's...

    Incorrect

    • The diaphragm is a muscle that is relatively resistant to non-depolarizing neuromuscular blockade's effects. When these muscle relaxants are used, which of the following peripheral nerve stimulator twitch patterns is best for monitoring the return of diaphragmatic function?

      Your Answer:

      Correct Answer: Post-tetanic count stimulation

      Explanation:

      Certain skeletal muscles are more resistant to the effects of neuromuscular blocking agents, both non-depolarizing and depolarizing. The diaphragm is the most resistant. The muscles of the larynx and the corrugator supercilii are less resistant. The abdominal, orbicularis oris, and limb peripheral muscles are the most sensitive muscles.

      Twitch stimulation patterns:

      Supramaximal single stimulus:

      The frequency ranges from 1 Hz to 0.1 Hz (one every second to one every 10 seconds)
      The response is proportional to the frequency of the event.
      It has limited clinical utility because it only tells you whether or not a patient is paralysed (no information on degree of paralysis).

      Over the course of 0.5 seconds (2 Hz), four supramaximal stimulate were applied:

      It is possible to see ‘fade’ and use it as a basis for evaluation.
      This stimulation pattern is used to determine the degree of blockade (1-2 twitches is appropriate for abdominal surgery)
      If the train of four (TOF) count is 1-2, reversal agents can be used in conjunction with medium-acting neuromuscular blocking agents.

      Ratio of TOF:

      This is the ratio of the 4th twitch amplitude to the 1st twitch amplitude.
      The ratio decreases with non-depolarising block and is inversely proportional to the degree of block, allowing objective measurement of residual neuromuscular blockade.
      To achieve adequate reversal, the ratio (as measured by accelerography) must be between 0.7 and 0.9.

      Count of twitches after a tetanic experience(PTC):

      50 Hz for 5 seconds, then a 3 second pause, followed by a single 1 Hz twitch stimulus.
      When the TOF count is zero, this stimulation pattern is used to assess deep blockade (that is, in neurosurgery, microsurgery or ophthalmic surgery when even small movements of a patient will disturb the surgical field)
      It gives an estimate of how long it will take for the response to return to single twitches, allowing assessment of blocks that are too deep for any other technique.
      A palpable post-tetanic count (PTC) of 2 indicates no twitch response for about 20-30 minutes, and a PTC of 5 indicates no twitch response for about 10-15 minutes.

      This is without a doubt the best way to keep track of paralysis in patients who need to avoid diaphragmatic movement. It’s best to use drug infusions and aim for a PTC of 2. After a tetanic stimulus, acetylcholine is mobilised, causing post-tetanic potentiation.

      Stimulation in Two Bursts:

      750 milliseconds between two short bursts of 50 Hz
      This stimulation pattern is used to assess small amounts of residual blockade manually (tactile).

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds
  • Question 40 - A 19-year-old woman presents to the emergency department. She complains of symptoms indicative...

    Incorrect

    • A 19-year-old woman presents to the emergency department. She complains of symptoms indicative of an acute exacerbation of known 'brittle' asthma. On history, she reveals her asthma is normally controlled using inhalers and she has never had an acute exacerbation requiring hospitalisation. On her admission into the ICU, further examination and diagnostic investigations are conducted. Her readings are: Physical state: Alert, anxious and non-cyanotic. Respiratory rate: 30 breaths/min, Pulse: 120 beats/min, Blood pressure: 150/90 mmHg, SPO2: 95% on air. Auscultation: Quiet breath sounds at both lung bases. What is the next most important step of investigation?

      Your Answer:

      Correct Answer: Peak expiratory flow rate

      Explanation:

      Peak expiratory flow rate (PEFR) is the maximum speed of air flow generated during a single forced exhaled breath. It is most useful when expressed as a percentage of the best value obtained from the patient.

      Forced expiratory volume over 1 second (FEV1) is a lung parameter measured using spirometry. It is the amount of air forced out of the lung in one exhaled breath. It is a more accurate measure of lung obstructions as it doesn’t rely on effort like PEFR

      PEFR and FEV1 are usually similar, but become more different in asthmatic patients as airflow becomes increasingly obstructed.

      Acute severe asthma is most often diagnosed on history taking and examinations:

      Respiratory rate: >25 breaths/min
      Heart rate: >110 beats/min
      PEFR: 33 – 50% predicted (<200L/min)
      Patient state: Unable to complete a sentence in a single breath.

      A chest x-ray is not routinely required, and is only indicated in specific circumstances, which are:

      If a pneumomediastinum or pneumothorax is suspected
      Possible life threatening asthma
      Possible consolidation
      Unresponsive asthma
      If ventilation is required.

      An echocardiograph (ECG) is not necessary in this case

      Routine haematological and biochemical investigations are not urgent in this case as any abnormalities they detect will be secondary to the patient's presentation.

      An arterial blood gas (ABG) will only be indicated if SPO2 was <92% or if patient presented with life threatening symptoms.

    • This question is part of the following fields:

      • Clinical Measurement
      0
      Seconds

SESSION STATS - PERFORMANCE PER SPECIALTY

Clinical Measurement (15/20) 75%